Fzz heat exchanger analysis
Choose one exchanger segment or a chain of segments. Calculate outlet temperatures, heat duty and local heat transfer.
The stationary model covers counterflow and parallel flow with constant heat-capacity rates or prescribed isothermal boundaries. Choose Segmented HEX to simulate an inlet-temperature step with fluid residence times.
HEX configuration
Flow arrangement
Formula selection and reference
Stationary results
- Heat transfer rate
- 207.515 kW
- Stream 1 to stream 2
- Stream 1 outlet
- 380.828 K
- Stream 2 outlet
- 357.643 K
- Total conductance UA
- 2,400 W/K
Temperature & heat transfer
Calculation formula in use
F2 · General counterflow
Exact relation selected.
H = 1,383.43331 W/K
Paired T–Q trajectories
Local results and verification
| Segment | UA (W/K) | T₁,in (K) | T₁,out (K) | T₂,in (K) | T₂,out (K) | Q̇ (kW) | Ṡgen (W/K) |
|---|---|---|---|---|---|---|---|
| 1 | 2,400 | 450 | 380.828 | 300 | 357.643 | 207.515 | 132.014 |
Balances and whole-network accuracy
Boundary energy residual is 2.037e-10 W. The normalized residual is 9.817e-16.
The exact single-contact reference at the same total UA gives 207.514997 kW. The relative network duty deviation is 0%, computed against that reference for this constant-capacity chain.
Formula selected for each segment
| Segment | Proposed | Applied | H (W/K) | Weight s | Candidate H error (%) | Applied H error (%) |
|---|---|---|---|---|---|---|
| 1 | F2 | F2 | 1,383.433313 | — | 0 | 0 |
Segment 1 · Exact relation selected.
Entropy & exergy
- Entropy generation
- 132.01403 W/K
- Exergy destruction
- 39.35998 kW
Fzz formulas, selector and transitions
Exact relations and limiting cases
G = UA; H = Fzz; Q̇ = H(T₁,in − T₂,in). For positive finite capacities:
F2 · x = G(1/C₁ − 1/C₂)
H = (1 − exp(−x)) / (1/C₁ − exp(−x)/C₂)
F3 · H = GC/(G + C), exact in counterflow when C₁ = C₂ = C.
F5 · H = [1 − exp(−G(1/C₁ + 1/C₂))] / (1/C₁ + 1/C₂)
F1 · H = C₁[1 − exp(−G/C₁)]
F4 · H = C₂[1 − exp(−G/C₂)]
F1 is exact for an isothermal stream 2 boundary; F4 for an isothermal stream 1 boundary. For finite capacities they are reservoir approximations. Two prescribed isotherms give H = G. F0 gives zero duty at zero capacity, but stationary outlet temperatures are undefined; this calculator requires positive finite flowing capacities.
At equal capacities the continuous F3 limit is used. G = 0 gives zero heat transfer. Exponential evaluations use expm1 and nonpositive-exponent branches for numerical robustness.
All selector regions and six transition formulas
Define ρ = max(C₁,C₂)/min(C₁,C₂). The equal-capacity approximation uses C = Cₑq = 2/(1/C₁ + 1/C₂).
| Region | C₁ < C₂ | C₁ > C₂ |
|---|---|---|
| Counterflow · 1 ≤ ρ ≤ 1.005 | F3 (exact at C₁ = C₂) | |
| Counterflow · 1.005 < ρ < 1.01 | F32 = (1 − s)F3 + sF2 | F23 = (1 − s)F3 + sF2 |
| Counterflow · 1.01 ≤ ρ ≤ 5 | F2 | |
| Parallel flow · 1 ≤ ρ ≤ 5 | F5 | |
| Counterflow · 5 < ρ < 10 | F12 = (1 − s)F2 + sF1 | F24 = (1 − s)F2 + sF4 |
| Parallel flow · 5 < ρ < 10 | F15 = (1 − s)F5 + sF1 | F54 = (1 − s)F5 + sF4 |
| Both arrangements · ρ ≥ 10 | F1 | F4 |
s = 6t⁵ − 15t⁴ + 10t³, clamped to [0, 1]. Near equal capacities, t = (ρ − 1.005)/0.005. Towards reservoir limits, t = (ρ − 5)/5. Symbols F1–F5 in these sums denote the corresponding H values.
A proposed formula is applied only when its relative H deviation from F2 (counterflow) or F5 (parallel flow) is within the selected tolerance and its physical bound is satisfied. Otherwise the exact relation is applied. The acceptance boundary can introduce a small jump even though the candidate transition is smooth.
F0 · Zero flow; stationary outlets undefined
F1 · Stream 2 reservoir limit
F2 · General counterflow
F3 · Equal-capacity counterflow
F4 · Stream 1 reservoir limit
F5 · General parallel flow
F12 · F2 to F1 transition
F24 · F2 to F4 transition
F23 · F3 to F2 transition; C₁ > C₂
F32 · F3 to F2 transition; C₁ < C₂
F15 · F5 to F1 transition
F54 · F5 to F4 transition
Coupling, entropy balance and inverse calculations
Stream 1 connects segment j to j + 1. Stream 2 connects j to j − 1 in counterflow, or j to j + 1 in parallel flow. The two outlet equations per segment are solved together as a linear system. Isothermal boundaries retain their prescribed temperatures.
For each flowing stream, ΔṠ = C ln(Tout/Tin). For an isothermal boundary, ΔṠ = Q̇received/T. Summing both contributions gives Ṡgen. Exergy destruction is T₀Ṡgen.
The inverse local route computes G = |Q̇|/ΔTlm from positive terminal differences. This is exact for the stated paired linear-in-duty interval; temperature-dependent trajectories require sufficiently fine intervals and refinement checks. A zero or crossed driving temperature difference is rejected.
Local selector error concerns H only. The shared model also reports the network duty deviation against the exact same-total-UA reference. It does not infer a complete cycle efficiency, COP or reversible-cycle benchmark from HEX results alone.
How this model is used in the Academy
Model assumptions and links to cycle calculations
This calculator and the Carnot external-stream contacts use the same Fzz core. Brayton external-stream conductance and the T–A mapping use its inverse local conductance relation on successive paired trajectory intervals. Their N₂ enthalpy and entropy properties remain temperature dependent; the entire Brayton trajectory is not replaced by a constant-cₚ exchanger.
For constant capacities and exact local formulas, the segmented chain reproduces the single-contact boundary result at the same total UA. Local temperatures and heat duties can differ. The displayed network deviation compares the selected chain against that exact reference; a local selector tolerance is not a guaranteed whole-network error bound.
The time simulation adds fluid storage and transport delays to the local Fzz contacts. It applies to two flowing streams with fixed properties and conductance. Wall storage, pressure loss and phase change require additional equations. Subdividing this chain keeps the stream properties constant.